GS Hospital AutoclavesFor CSSDs, OR & Medical Centers
160 liter (1 StU) or 250 liter (2 StU) chambers
Pass-through between sterile & non-sterile areas
Single and Double Door
Sterilization of wrapped and unwrapped equipment
Cost-effective pricing
Hospital grade performance
GS-LINE HOSPITAL AUTOCLAVES
GS autoclaves are designed for Hospital CSSD, OR, and Medical Centers with limited budgets that need reliable sterile processings. We have maintained Tuttnauer’s high quality for hospital grade autoclaves, providing reliable, heavy-duty high performance machines. The rounded chamber and coiled jacket reduce the manufacturing costs which allow for more affordable autoclaves.
MORE AFFORDABLE
For Facilities with Limited Budget
• Tuttnauer passes that benefit on to our customers
NARROW DESIGN
Designed for Limited Space
• More autoclaves reduce downtime risks by ensuring continued sterile processing
SIMPLIFIED DESIGN = LOW MAINTENANCE
Hospital Grade Performance with Simplified Design
• Low long-term maintenance costs
CONVENIENT 1 WALL PASS-THROUGH INSTALLATION
• Includes side panels for 1-wall installation
• Additional service area not required
• Can also be installed in a 2 wall separation
FEATURES
- Automatic locking hinged doors
- 7” Touch screen on both sides
- 18kW built-in steam generator
- Built-in wheels
- Built-in water-ring vacuum pump
- 316L Stainless steel chamber
- 304L Stainless steel housing
- Built-in printer
5075GS AUTOCLAVE
• 160 Liter chamber • 1 StU basket • 2 ISO baskets
5075GS AUTOCLAVE
• 160 Liter chamber • 1 StU basket • 2 ISO baskets
TECHNICAL SPECIFICATIONS
Model | Chamber Dim. ø x L (mm) |
Chamber Vol. (Liters) | Tray Dimensions WxHxD (mm) |
Baskets | Power (kW) | Voltage/Freq. Volts/Hz |
50125GS-1A (1 door) 50125GS-2A (2 doors) |
500 x 1250 | 250 | 2 x [310 x 21 x 610]
2 x [471 x 21 x 610] |
2 StU
4 ISO |
18 kW | 3 ph, 208/230/400 Volts 1ph, 230 Volts* 50/60 Hz |
5075GS-1A (1 door) 5075GS-2A (2 doors) |
500 x 810 | 160 | 310 x 21 x 773 471 x 21 x 773 |
1 StU 2 ISO |
18 kW | 3 ph, 208/230/400 Volts 1ph, 230 Volts* 50/60 Hz |
* requires switch box – optional
Note: The 50125GS requires a compressed air supply of 6 Bar to operate pneumatic valves.
SAFETY
Safety for personnel, autoclave and load are priority in the design, construction and operation of any Tuttnauer autoclave. Tuttnauer is committed to the highest industry safety standards and directives to ensure safety not only for your employees operating the autoclaves but also for your laboratory and the loads being sterilized.
- A safety device prevents the operator from opening the door when the chamber is pressurized
- Steam will not enter the chamber when the door is open
- A cycle cannot start if the door is open or not properly locked
- The door cannot unlock until liquid temperature reaches the predetermined end temperature
- Two independent flexible PT100 temperature sensors to prevent over-boiling of liquids and explosions of bottles